Maintenance
Update troubleshooting
Start in Control UI → Settings → Updates. The page reads the latest recorded update attempt from the connected Gateway and shows its time, target, reason code, failing step, and bounded diagnostic detail.
Control UI remediation uses typed product actions only. It leads with an authenticated Gateway or native action when the connected UI has the required capability and scope, preserves confirmations for disruptive operations, and keeps terminal commands as secondary host-side fallbacks. It never parses localized guidance or executes an arbitrary command string.
Recover in the Control UI
- Select Check status when the Gateway restarted, disconnected, or did not
report a final result. This reads
update.status; it does not start another update. Recovery controls stay disabled while the check is pending, and a rejected request appears as an error on the page. - Open View details and address the recorded failing step. Diagnostic text is bounded and redacted for display; use Gateway logs when more context is required.
- Select Retry update only after the cause is resolved. The Control UI uses the normal confirmed update flow and states that running sessions are interrupted while the Gateway restarts.
The controls require a connected Gateway, support for the corresponding typed Gateway method, and administrator scope. When those conditions are not met, use the CLI fallback on the Gateway host.
Reason codes
dirty,no-upstream: repair the source checkout before retrying.deps-install-failed,build-failed,ui-build-failed: inspect the failing step, fix the dependency or build error, then retry.global-install-failed: retry after checking package-manager ownership and permissions. Re-run the installer if the package install is incomplete.doctor-failed: run Doctor on the Gateway host, resolve its findings, then retry.restart-disabled,restart-unavailable: restore a supported supervisor or enable Gateway restarts before retrying.restart-unhealthy,restart-revision-mismatch,restart-revision-unavailable: inspect Gateway service health and its install root before retrying.managed-service-handoff-*: check status first. If the handoff stopped, use the CLI on the Gateway host to preserve the full diagnostic output.
Unknown reason codes remain visible. Check the Gateway logs before retrying.
CLI fallback
Run these commands on the Gateway host, not on the computer that merely has the Control UI open:
openclaw update status --jsonopenclaw doctor --non-interactiveopenclaw updateUse openclaw update --dry-run to preview a new attempt. If a package update
failed after installation began, follow the installer recovery steps in
Updating.
Rollback boundary
Do not restore state as the first response to an update failure. First reinstall known-good code while preserving current state. Restore a verified pre-update state snapshot only when older code cannot read the current config or database. See Rollback.
Support diagnostics
Collect the following without posting credentials, raw config, or unredacted process output:
- OpenClaw version and install type;
- update timestamp, target, phase, and reason code from Settings → Updates;
- the bounded failure detail shown by View details;
openclaw update status --json;openclaw gateway status --deep --json;- relevant redacted Gateway log lines.